Schwank Authorized Regional Distributor: Engineering & Design Support

ChopAir is a verified, nationally authorized distributor for Schwank radiant heating systems and architectural air curtain solutions. We provide comprehensive engineering submittals, parametric BIM models, and large-scale thermal system designs for industrial warehouses, manufacturing plants, and high-traffic commercial facilities nationwide. Our thermal engineering specialists offer factory-direct Schwank pricing, radiant system calculations, air curtain specifications, and expedited national logistics for industrial construction and major facility energy upgrades.

(816) 643-3875

Call for assistance with your HVAC project.

Verified Schwank Dealer

Nationwide Distribution

Local Design Assistance

National Design & Engineering Support for Schwank products

Our thermal systems engineering division creates the technical link between Schwank’s industrial heating technology and demanding facility performance specifications. We excel in radiant tube system layouts, high-bay thermal modeling, air curtain vestibule design, and regulatory compliance documentation addressing ASHRAE 62.1 ventilation standards, LEED energy performance credits, and regional mechanical energy regulations. Find product-level technical documentation and field deployment insights below. Comprehensive specification guides, warranty policies, and certified performance data reside on individual product pages at shop.chopair.com.

(816) 643-3875

Call now for nationwide service.

Schwank National Logistics & Technical support

Sustaining Tier-1 Schwank distributor authorization demands that ChopAir maintain a robust national logistics platform engineered to accelerate transit schedules and control shipping costs for industrial-scale radiant heating equipment.

Midwest Hub (Kansas City, MO)

Centralized logistics for rapid 2-3 day transit to either coast.

Southwest Hub (Houston, TX)

Specialized support for Gulf Coast industrial and chemical facilities.

Southeast Hub (Apopka, FL)

Regional fulfillment for hospitality and coastal-rated heating systems.

National Engineering & Design Desk

Our national reach is backed by a centralized engineering team that provides.

Remote Layout Assistance: Send us your CAD or PDF blueprints; we provide a full heat-loss calculation and Schwank equipment placement guide.

Submittal Packages: We generate the technical documentation required for municipal permits and architectural approval.

Industrial Freight & Job Site Delivery

Unlike conventional HVAC retailers, ChopAir orchestrates complex LTL freight operations and dedicated flatbed logistics for oversized radiant tube heaters measuring up to 80 feet in length.

Industrial Site Coordination: Our logistics team schedules lift-gate delivery services and manages delivery time windows ensuring radiant heating equipment arrives precisely when mechanical installation crews are mobilized for overhead mounting operations.

Every Schwank shipment receives enhanced structural reinforcement designed to eliminate the tube deformation and ceramic tile fracturing that commonly occurs when industrial radiant equipment ships via standard parcel networks.

Schwank Heater Categories

Schwank Air Curtains

Schwank air curtains create high-velocity barriers across building entrances, preventing 90% of conditioned air loss and eliminating insect penetration. These systems serve retail stores, hotel lobbies, and logistics facilities requiring accessible entrances without climate control sacrifice. Properly specified air curtains reduce heating and cooling costs 20-40% compared to unprotected openings.

Schwank Breeze 9

Schwank Epic 14

Schwank Select 10

Schwank High-Intensity Heater

Schwank high-intensity luminous infrared heaters deliver maximum thermal output in facilities with 30-180 foot ceilings. Ceramic tile arrays reach 1800°F, providing instant radiant heat ideal for aircraft hangars and freight terminals. The visible orange radiance and no-preheat operation suit facilities with high air exchange rates.

Schwank High-Intensity Heater

Schwank High-Intensity Stadium Heater

Schwank Gas-Fired Indoor/Outdoor Unit Heaters

Schwank gas-fired tube heaters span applications from climate-controlled garages to industrial washdown facilities. Specialized series include Stainless-Steel Wet Environment and Tough Harsh Environment models for food processing and wastewater treatment. Straight tubes create linear heat patterns for narrow aisles, while U-Tubes deliver equivalent BTU in half the footprint.

Schwank Outdoor Patio, Wet/Damp Env. Tube Heater

Schwank Straight Emissive Coated Tube Heater

Schwank Extreme Environment Tube Heater

National Engineering Guide: Schwank Heater Model Comparison

Schwank Low-Intensity Tube Heaters vs. High-Intensity Luminous Heaters

The most critical industrial heating specification decision involves selecting between Low-Intensity Tube radiant systems and High-Intensity Luminous ceramic technology.

FeatureLow-Intensity Tube (SST/ST)High-Intensity Luminous (ecoSchwank)
Heat MechanismHot products of combustion inside a tube.Glowing ceramic tiles (up to 1800°F).
Visual SignalNo visible light; enclosed flame.Visible orange glow from ceramic plaques.
Best ApplicationGeneral warehouse heat (12'–50').High-bay logistics or spot heating (30'–180').
VentilationCan be vented outdoors or unvented.Usually unvented (requires building air exchange).

ChopAir Engineering Field Insight: The "Warm-Up" Variable

"We specify Luminous Heaters for industrial zones experiencing high air turnover rates—loading dock environments exemplify this application. The absence of tube preheat requirements enables nearly immediate radiant delivery. Conversely, for comprehensive facility heating in manufacturing environments requiring uniform thermal coverage, Gas Tube Heaters provide superior performance through their extended heat exchange surface area."

Get Project Assistance >

(816) 643-3875

Call for assistance with your HVAC project.

Positive Pressure (SST) vs. Standard Gas Tube Heaters

Distinguishing between Schwank's Positive Pressure burner architecture and conventional vacuum-draw emissive tube systems proves essential for maintenance lifecycle planning.

TechnologyPositive Pressure (SST/SPP)Standard/Straight Tube (ST)
Burner LogicPushes air/gas mix through the tube.Pulls air through the tube via vacuum.
Component ProtectionBurner is isolated from flue gases.Burner components are in the exhaust path.
MaintenanceLower; components stay cleaner.Moderate; requires more frequent inspection.

ChopAir Engineering Field Insight: The Lifespan Gap

"The SST Positive Pressure product line represents our national specification standard for heavy industrial applications. By pressurizing combustion airflow, burner components remain isolated from corrosive combustion byproducts. Field data demonstrates SST units sustaining peak thermal efficiency 5–7 years beyond traditional vacuum-style tube heaters in facilities operating continuous duty cycles."

Get Project Assistance >

(816) 643-3875

Call for assistance with your HVAC project.

Straight Tube vs. U-Tube Geometry

The physical footprint of the heater dictates the layout of the facility's piping and electrical drops.

GeometryStraight Tube SeriesU-Tube Series
Heat ProfileLong, linear heat footprint.Concentrated, high-density heat.
InstallationRequires long runs (up to 80ft).Compact footprint (approx. half the length).
Optimal UseNarrow aisles, production lines.Workstations, bay doors, perimeter walls.

Fill in

"Radiant tube geometry determines facility mechanical layout planning. Straight tube installations create extended linear heat footprints ideal for warehouse aisles and production lines. U-tube geometry concentrates equivalent heating capacity into compact mounting footprints—approximately half the length—optimized for workstation heating and perimeter bay door applications."

Get Project Assistance >

(816) 643-3875

Call for assistance with your HVAC project.

Which Schwank heater model is best?

Below is a quick reference table. For more detail, use our Product Comparison tool on ChopShop, or the AI-powered virtual assistant ChopBot, for deep technical analysis.

Use CaseRecommended Schwank Category / ModelKey Technical Benefit
High-Traffic Loading DocksHigh-Intensity Luminous HeatersInstantaneous radiant heat delivery without a pre-heating period.
General Warehouse HeatingLow-Intensity Tube Heaters (SST/SPP)Provides a uniform "thermal blanket" over large surface areas.
Harsh/Heavy Industrial EnvironmentsPositive Pressure (SST) SeriesBurner is isolated from corrosive flue gases, extending lifespan by 5–7 years.
Food Processing / Wash-Down ZonesStainless-Steel Wet Environment SeriesEngineered with corrosion-resistant housings to withstand direct moisture.
Space-Constrained Work CellsU-Tube GeometryConcentrates high BTU output into nearly half the physical length.
Narrow Corridors / AislesStraight Tube SeriesProvides a long, linear heat footprint for uniform coverage.
Sustainable / "Net Zero" ProjectsElectric Infrared (eSchwank)Zero on-site emissions and no requirement for gas piping or venting.
High-Bay Logistics (>30' Heights)High-Intensity (Luminous) HeatersOptimized for extreme mounting heights up to 180 feet.
Commercial / Retail EntrywaysSchwank Air CurtainsPrevents up to 90% of conditioned air loss via a laminar air seal.

Meet the ChopBot

The Industry’s First AI-Powered Procurement Assistant

  • Run analysis on multiple model specs at once
  • Get fast advice on which models match your energy limitations
  • Put together quotes and projects instantly

Shop Schwank HVAC Today

ChopAir's all-inclusive buying platform includes expert human review for every order.

(816) 643-3875

Call for assistance with your HVAC project.

X